Brand Name: Clitech
Model Number: CAM-100XB
Place of Origin: Guangdong, China (Mainland)
Modular design, combine with chiller unit for project like hotel, cooling space in summer, and supply hot water always.
Technical Parameters:
Website:www.clitechchina.en.alibaba.com
Word: Air / water heat pump for commercial heating cooling and hot water.
Model | CAM-100XB | |
AC cooling | Cooling capacity kW | 66.2 |
AC Water flow M³/H | 11.39 | |
Input power KW | 22.4 | |
Rated input current A | 41 | |
EER | 2.96 | |
AC cooling with heat recovery for hot water | Cooling capacity kW | 69.3 |
AC Water flow M³/H | 10.53 | |
Heating capacity kW | 77.6 | |
Hot water output T/H | 1.7 | |
Input power KW | 17.3 | |
Rated input current A | 32 | |
EER+COP | 8.02 | |
AC heating with Hot water | Heating capacity kW | 90.00 |
Hot water output T/H | 1.94 | |
Input power KW | 18.66 | |
Rated input current A | 34.87 | |
COP | 4.82 | |
Rated & Max water temp °C | 55°C and 60°C | |
Power source V/PH/HZ | 380V/3N/50HZ | |
Noise level dB(A) | <60 | |
Unit size W x D x H mm | 2205*1030*2090 | |
Wood Packing W x D x H mm | 2300*1140*2260 | |
Net weight Kg | 930 | |
Throttle Type | Electronic expansion valve/Thermal expansion valve | |
Refrigerant Qty kg | 6*4 | |
Sanyo Compressor Pcs | 4 | |
Protection | Built-in protection as overheating protection, sequence protection, undervoltage protection, time-delay start protection etc | |
Condensor | Heat exchanger type | Finned tube heat exchanger |
Qty pcs | 1 | |
Fan type | Axial big twist angle fan | |
Motor KW | 1.5 | |
Hot water | Heat exchanger type | Axial big twist angle fan |
Qty pcs | 1 | |
Water flow M³/H | 15.48 | |
Pressure Loss KPa | 48 | |
Pipe size mm | 50 | |
Air Conditioner | Heat exchanger type | Axial big twist angle fan |
Quantity | 1 | |
water flow M³/H | 10.53 | |
Pressure Loss Kpa | 47 | |
Pipe size mm | 50 | |
Water side max working temp kPa | 1000 | |
1.Rated cooling working condition: Air source side inlet water temp is 35°C, AC side inlet water temp is 12°C, outlet water temp is 7°C | ||
2.Rated heating&hot water condition: Air source side DB/WB is 20°C/15°C,initial hot water temp 15°C, ending hot water temp 55°C;AC side inlet water temp 40°C,outlet water temp 45°C. | ||
3.Rated cooling&hot water working condition: initial hot water temp 15°C,ending hot water temp 55°C;AC side inlet water temp 12°C,outlet water temp 7°C. |
Each project has its special requirement for installation, if any queries, our engineer will be so glad to make any drawing or suggestion for you! Pls kindly contact us!